Determination of bromine and iodine in four marine sediment reference samples by energy-dispersive X-ray fluorescence spectrometry
D.H. Doff
Department of Geology, Trinity College, Dublin 2, Ireland
Abstract
The concentrations of bromine and iodine in the USGS marine mud
MAG-1, the NRCC marine sediments BCSS-1 and MESS-1, and the NBS
estuarine sediment SRM 1646 have been determined by energy-dispersive
X-ray fluorescence spectrometry. Matrix and intermediate thickness
effects were overcome by standard additions to constant weights
of each sample. 3-sigma detection limits are 6 ppm Br and 24 ppm
I. There is a need for many more analysts to report their results
before "usable values" can be established for these
elements in marine sediment reference materials.
Résumé
Les teneurs en brome et iode de quatre étalons de sédiments
marins (boue marine MAG-1 (USGS), sédiments marins BCSS-1
et MESS-1 (NRCC) et sédiment estuarien SRM 1646 (NBS))
ont été dosé es par spectrométrie
de fluorescence - X à dispersion d'énergie. Les
effets de matrice et d'épaisseur intermédiaire ont
été éliminés par l'addition standard
pour obtenir un poids identique pour chaque échantillon.
La limite de détection (3 écarts-type) est de 6
ppm pour le brome et de 24 ppm pour l'iode. Des valeurs utilisables
ne peuvent pas encore être proposées faute d'un nombre
de données suffisantes sur ces deux éléments.